Common-Rail
Equipment for testing of Common Rail pumps
FMDE1200A
  • Description
  • Package contents
  • Extra

FMDE1200A. Dial 2-channel flowmeter.

The device “FMDE-1200A” is designed for testing and checking the performance of high pressure fuel pumps of the Common Rail system.

The device has two channels for measuring the flow. The first channel has a two-stage measurement of the fluid flow to provide a larger measuring range for the fluid flow. In each measuring channel of the flow there is a temperature sensor that measures the temperature of the incoming fluid flow.

Controller «FMDE-1200A» 1 pc.
Power cable 220 V 1 pc.
USB cable 1 pc.
Filter (50 mc) 2 pc.
Software «DieselTest» 1 pc.
Manual «FMDE-1200» 1 pc.

Main technical data and characteristics

Measured flow range:
Channel 1. Sensor 1. 0,1 – 2,5 l/min. 6-150 l/h.
Channel 1. Sensor 2. 0,5 – 20 l/min. 30-1200 l/h
Channel 2. Sensor 3. 0,5 – 20 l/min. 30-1200 l/h
Flow measurement tolerace:
Channel 1. Sensor 1. 3%
Channel 1. Sensor 2. 6-150 l/h no more then: +/- 2l/h
Channel 1. Sensor 2. more then 150 l/hour: no more then 1%
Channel 2. Sensor 3. 6-150 l/hour: no more then: +/- 2l/h;
Channel 2. sensor 3. more then 150 l/hour: no more then 1%
Repeatability 0,5%
Permissible flow temperature range -20 – +90 °C
Tolerance of flow temperature measurement, no more than +/-2°C
Supply voltage ~220 V  ±15%
Weight 6 kg
Dimentions (length х width х height) 365х322х110
Power consumption, no more than 24 Wt